Surface Plates & Tables Calibration

BS 817:2008

Trusting Rhopoint Metrology for your surface plate and table calibration ensures precision, compliance, and peace of mind, supporting your commitment to quality and operational excellence.ย We offer ISO 17025 certified calibration.

Read more about caring for your surface plate

Surface Plates & Tables Calibration Services

Surface Plates & Tables

To Top
UKAS Calibration for Surface Plates / Tables – Plate – 300 x 300 mm (12 x 12″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Plate – 450 x 300 mm (18 x 12″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Plate – 450 x 450 mm (18 x 18″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Plate – 600 x 450 mm (24 x 18″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Plate – 600 x 600 mm (24 x 24″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Plate – 750 x 600 mm (30 x 24″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Plate – 750 x 750 mm (30 x 30″)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 900 x 600mm (3 x 2′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1200 x 1200mm (4 x 4′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1200 x 600mm (4 x 2′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1200 x 900mm (4 x 3′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1500 x 1200mm (5 x 4′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1500 x 900mm (5 x 3′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1800 x 1200mm (6 x 4′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 1800 x 900mm (6 x 3′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 900 x 900mm (3 x 3′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 2400 x 1200mm (8 x 4′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 2400 x 1800mm (8 x 6′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 2400 x 900mm (8 x 3′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 3000 x 1800mm (10 x 6′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 3600 x 1200mm (12 x 4′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 3600 x 1800mm (12 x 6′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 3600 x 2700mm (12′ x 9′)UKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 3600 x 3300mm (12′ x 11′)UKASAdd to Quote
UKAS Calibration for Surface Tables / Plates – Table – 22 x 4 metresUKASAdd to Quote
UKAS Calibration for Surface Plates / Tables – Table – 6 x 2.5 metres (20′ x 8′)UKASAdd to Quote
UKAS Calibration for 3.7 x 22 metres Surface Table – Machined BedUKASAdd to Quote

New Surface Plates & Tables instruments available to buy online today with UKAS calibration

Need assistance with your calibration?

If you haven’t found the calibration you require or need some further assistance with your requirement, contact us using this form and we can find the solution you are looking for.ย 

To ensure we can promptly address your calibration enquiry, please complete the form with all the necessary details. This will help us to provide you with accurate and timely assistance.

For urgent enquiries, please contact us directly via phone at:

The Care and Use of Surface Tables and Plates

British Standard Reference : BS 817 : 2008

  1. A Surface Plate is a datum and should be protected against damage. The top should be frequently wiped clean from dust and other particles. When measurements are being made, a cloth should be spread on the Surface Plate to receive small tools and gauges. When the Surface Plate is not in use the top should always be kept covered
  2. A grade ‘0’ or grade ‘1’ Surface Plate should be located in a circulating atmosphere under constant temperature control. Accordingly, it should be kept clear of direct sunlight or sudden draughts, in particular it is important that these should not cause a vertical gradient of temperature such that the top and underside of the Surface Plate are at difference temperatures
  3. Stands should be located on a stable foundation. The Surface Plate should be supported firmly and levelled
  4. Care should be taken that, wherever possible, the load on a Surface Plate is distributed over the working surface
  5. Point contact should not be made with scraped or machined Surface Plates because of the high proportion of low, unrepresentative areas of the working surfaces. Contact should be made through an intermediate Gauge Block, preferably not more than 10mm in length, or a distance piece of similar precision and surface area
  6. Use should be made of the full available area of the working surface and not concentrated on any one area
  7. A common form of damage to Cast Iron Surface Plates is burrs on the working surface, the excess metal may be stoned away by attention confined to the burr. This operation should be followed by thoroughly cleaning away any abrasive dust. If the Surface Plate is not required for some days, the surface should be coated with a corrosion preventative such as petroleum jelly
    Rusting is a sign of neglect and misuse. Its effect can be reduced by frequently wiping the top when in use
  8. A common form of damage to Granite Surface Plates is cuts in the working surface, these can be minimised only by care in the use of the Surface Plates
  9. Cleaning of Granite Surface Plates should be performed with the use of the specialised compounds available from the manufacturers
  10. A border zone of up to 10mm on the edges of Surface Plates/Surface Tables should be avoided when taking measurements
  11. Never use a surface plate/surface table that has not been calibrated, if in doubt consult an appropriate authority.

It is necessary that any person carrying out such calibration work should have received appropriateย training and have shown the ability to be confident via a suitable training authority. Training recordsย should be held and maintained.

UKAS Calibration

All of our Laboratories are accredited to provide UKAS & Traceable calibrations to all the relevant standards giving you peace of mind.

Benefits of Calibration

Accurate & Reliable

Make consistent, accurate and reliable measurements

Increase Product Life

Ensure longevity of the measuring instruments

Safety and Reliability

Ensure safety in critical applications such as medical and aerospace