Plain Plug GaugesTo Top | ||||
UKAS Calibration for Plain Plug Gauges – Parallel – Single Ended – up to 100 mm (up to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Single Ended – 100 – 150 mm (4 – 6″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Single Ended – 150 – 250 mm (6 – 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Single Ended – above 250 mm (above 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Double Ended – up to 100mm (up to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Double Ended – 100 – 150 mm (4 – 6″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Double Ended – 150 – 250mm (6 – 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Parallel – Double Ended – above 250 mm (above 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Progressive Plain Plug Gauge – (3 Diameters) – up to 50mm (up to 2″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Plain Taper – up to 100 mm (up to 4″ ) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Plain Taper – above 100 mm (above 4″) | UKAS | Add to Quote | ||
Plain Ring GaugesTo Top | ||||
UKAS Calibration for Ring Gauges – Plain – Setting Rings – 2 UpTo 100 mm (0.078″ to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Ring Gauges – Plain – Setting Rings – 100 – 150 mm (4″ – 6″) | UKAS | Add to Quote | ||
UKAS Calibration for Ring Gauges – Plain – Setting Rings – 150 – 250 mm (6″ – 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Ring Gauges – Plain – Setting Rings – above 250 mm (above 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Double Diameter Plain Setting Ring – Go/Not Go – up to 100 mm (up to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Double Diameter Plain Setting Ring – Go/Not Go – 100 – 150 mm (4″ – 6″) | UKAS | Add to Quote | ||
UKAS Calibration for Ring Gauges – Plain – Plain Taper – up to 4″ (up to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Ring Gauges – Plain – Plain Taper – above 4″ (above 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Air Setting Ring & Plug Set | UKAS | Add to Quote | ||
UKAS Calibration for Special Min/Max Taper Ring Gauge | UKAS | Add to Quote | ||
Luer TaperTo Top | ||||
UKAS Calibration for Ring Gauges – Plain – Luer Taper | UKAS | Add to Quote | ||
UKAS Calibration for Plain Plug Gauges – Luer Taper | UKAS | Add to Quote | ||
Pin GaugesTo Top | ||||
UKAS Calibration for Pin Gauges (Drill Blanks) – each | UKAS | Add to Quote | ||
UKAS Calibration for Taper Graduated Pin | UKAS | Add to Quote | ||
Rok-It GaugesTo Top | ||||
UKAS Calibration for Plain Rok-It Gauge – Double Ended – up to 100mm (up to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Rok-It Gauge – Double Ended – 100 – 150 mm (4 – 6″) | UKAS | Add to Quote | ||
UKAS Calibration for Adjustable Rok-It Gauge | UKAS | Add to Quote | ||
UKAS Calibration for Plain Rok-It Gauge – Double Ended – 150 – 250mm (6 – 10″) | UKAS | Add to Quote | ||
UKAS Calibration for Plain Rok-It Gauge – Double Ended – above 250 mm (above 10″) | UKAS | Add to Quote | ||
Gap GaugesTo Top | ||||
UKAS Calibration for Gap Gauges – Plain / Adjustable – up to 100 mm (up to 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Gap Gauges – Plain / Adjustable – Above 100 mm (Above 4″) | UKAS | Add to Quote | ||
UKAS Calibration for Charpy Test Piece – ‘U’ Notch | UKAS | Add to Quote | ||
UKAS Calibration for Charpy Test Piece – ‘V’ Notch | UKAS | Add to Quote |
If you haven’t found the calibration you require or need some further assistance with your requirement, contact us using this form and we can find the solution you are looking for.ย
To ensure we can promptly address your calibration enquiry, please complete the form with all the necessary details. This will help us to provide you with accurate and timely assistance.
For urgent enquiries, please contact us directly via phone at:
This standard specifies the tolerances and limits for simple forms of limit gauges, such as:
It is intended for reference by component producers and gauge makers when gauge limits have not been stipulated. It specifies gauge tolerances for work piece tolerances in ranges between 0.009mm and 3.200mm and how gauge limits are related to the work piece limits. It also specifies types of gauge according to size and minimum work piece tolerance, dimensions are expressed in millimetres but appropriate values in imperial units are given in appendix C.
It is highly recommended that an appropriate authority such as a UKAS approved laboratory carries out a full calibration on plain limit gauges at least once a year. In between UKAS calibrations at a frequency based on usage, plain limit gauges should be calibrated in-house. A typical in-house calibration would include a written procedure and an associated calibration record sheet, which would contain as a minimum, the following listed information:
(a) Serial number
(b) Location
(c) Procedure number
(d) Workpiece tolerance
(e) Gauge tolerance
(f) Results
(g) Measurement uncertainty
(h) Sentence if appropriate
(i) Date and calibrators signature
(j) Traceability to National Standards
It is necessary that any person carrying out such calibration work should have received appropriate training and have shown the ability to be confident via a suitable training authority. Training records should be held and maintained.
Following are layouts for typical in-house calibrations for plain limit gauges:
Calibration to be carried out in accordance with in-house procedure number …………………..
Serial Number: Make:
Calibration Date: Sizes:
FEATURE EXAMINEDย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย SPEC.ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย MEASURED RESULTS
GO:
NOT GO:
The plain limit gap gauges were visually inspected for damage and the following faults were noted:
MEASUREMENT UNCERTAINTY +/- 0.003mm (0.5-100mm range)
Source: UKAS schedule of accreditation, Calibration and measurement capability (CMC)
Calibrators Signature: ………………………………….
A traceability statement in this section would be required for all items and their relevant certification utilised for the calibration of plain limit gap gauges.
Calibration to be carried out in accordance with in-house procedure number …………………..
Serial Number: Make:
Calibration Date: Sizes:
FEATURE EXAMINEDย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย SPEC.ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย MEASURED RESULT
ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย FRONTย ย ย ย MIDDLEย ย ย ย ย ย ย ย BACK
GO:
@ 90 degrees:
NOT GO:
@ 90 degrees:
The plain limit plug gauges were visually inspected for damage and the following faults were noted:
MEASUREMENT UNCERTAINTY +/- 0.0005mmย (1-25mm range)
Source: UKAS schedule of accreditation, Calibration and measurement capability (CMC)
ย
Calibrators Signature: ………………………………….
A traceability statement in this section would be required for all items and their relevant certification utilised for the calibration of plain limit plug gauges.
Calibration to be carried out in accordance with in-house procedure number …………………..
Serial Number: Make:
Calibration Date: Sizes:
FEATURE EXAMINEDย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย SPEC.ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย MEASURED RESULT
ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย ย FRONTย ย ย ย MIDDLEย ย ย ย ย ย ย ย BACK
GO:
@ 90 degrees:
NOT GO:
@ 90 degrees:
The plain ring plug gauges were visually inspected for damage and the following faults were noted:
MEASUREMENT UNCERTAINTY +/- 0.0008mmย (2-25mm range)
Source: UKAS schedule of accreditation, Calibration and measurement capability (CMC)
ย
Calibrators Signature: ………………………………….
A traceability statement in this section would be required for all items and their relevant certification utilised for the calibration of plain ring gauges.
All of our Laboratories are accredited to provide UKAS & Traceable calibrations to all the relevant standards giving you peace of mind.
Make consistent, accurate and reliable measurements
Ensure longevity of the measuring instruments
Ensure safety in critical applications such as medical and aerospace
Rhopoint Metrology Ltd Eurolab House, Unit 10 Valepits Road, Garretts Green Industrial Estate, Birmingham, B33 0TD
Rhopoint Metrology Ltd Brunel House, 28 Old Mills Industrial Estate, Paulton, BS39 7SU